CFS5.5 cfs-55-1s cfs-55-2s-2 cfs-55-3s-2 oxy_2s_2024
CFS5.5 cfs-55-1s cfs-55-2s-2 cfs-55-3s-2 oxy_2s_2024

CFS5.5

Breathing Air Catalog lr 2026_0

The BAUER CFS 5.5 (Containment Fill Station 5.5) is a premier safety enclosure engineered to provide maximum operator protection during high-pressure breathing air cylinder refilling. Subjected to catastrophic rupture testing by an independent third-party laboratory, the CFS 5.5 fully complies with and exceeds NFPA 1901 standards. Constructed from heavy-duty, reinforced welded structural steel plates, this station effectively contains highly volatile shockwaves and sharp metal fragments in the event of a cylinder or valve failure at pressures up to 5500 PSIG (379 BAR). Equipped with a patented pneumatic safety interlock door and an intuitive flow control panel, the CFS 5.5 provides the ultimate safety defense shield for fire SCBA and SCUBA filling operators.

  • NFPA 1901 Certified Protection: Formidable armored steel plates combined with engineered venting directs dangerous explosion energies away from operators.
  • Pneumatic Safety Interlock Lock: Automatically interrupts filling flow if the chamber door is not fully closed and locked, eliminating human operational errors.
  • Ergonomic Loading Station: Built with tilted low-profile loading trays and low-friction wear sleeves, reducing the physical strain on operators loading heavy cylinders.

Scope of Application

  • Municipal fire stations, specialized rescue squads, and mobile emergency SCBA refilling trucks
  • Commercial diving centers, boat filling stations, and tactical naval underwater logistics support bases
  • Safety stations inside hazardous industrial facilities, chemical plants, and nuclear power plants
  • Defense maintenance centers, ordnance support bases, and specialized high-pressure gas laboratories
CFS5.5-1SCFS5.5-1S
CFS5.5-2SCFS5.5-2S
CFS5.5-3SCFS5.5-3S
OXY-2SOXY-2S

Zero Compromise on Personnel Safety: BAUER CFS 5.5 High-Pressure Containment Fill Station

  • Fire Service High-Turnover Refilling: Safeguards firefighters during continuous, high-speed refilling of carbon-fiber SCBA cylinders after training or fire ground deployment.
  • Cascade Storage Management: Supports swift pressure-differential refilling utilizing high-pressure storage cylinder banks safely.
  • Industrial Emergency Response: Supplies secure containment for refilling chemical protection suits air cylinders during hazmat response.

Value&Benefits

The BAUER CFS 5.5 is more than a fill station; it is the ultimate life insurance for your filling technicians. At high pressures, a cylinder failure is comparable to a grenade detonation. Standardizing on the armored CFS 5.5 reduces this catastrophic risk to zero, protecting lives and eliminating enormous potential legal and operational shutdown costs.

  • Ultimate Liability & Life Protection: Armored containment walls keep structural cylinder rupture damage fully enclosed, securing a zero-injury workspace.
  • Enhanced Workflow Speed: Tilted, low-height loading trays make loading/unloading rapid, reducing turnaround times and raising station daily capacity.
  • Seamless Compatibility: Integrates flawlessly with existing high-pressure breathing compressors and cascade cylinders without complete station replumbing.

Performance

  • Successfully tested against catastrophic failure of a 122 cu. ft. carbon-fiber cylinder pressurized to 5500 PSIG.
  • Built-in heavy isolation base dampers effectively isolate operating and accidental ground vibrations.
  • Integrated heavy-gauge stainless steel manifold panel features precise pressure gauges, manual regulator valves, and intake silencers.

Specifications

  • Max Pressure Protection Rating: 5500 PSIG (379 BAR) / 7000 PSIG containment safety margin
  • Configuration Options: Available in 1-position (1S), 2-position (2S), and 3-position (3S) models
  • Safety Mechanism: Pneumatic safety interlock system with micro-flow cut-off valves
  • Hardware Specs: Standard with 5000/6000 PSIG rated stainless steel wire-braid fill hoses, safety vent valves, and fill adapters
  • Chassis Finish: Heavy welded structural steel coated with rugged chemical-resistant industrial powder finish

Certifications

  • Certified compliant with NFPA 1901 standards for fire apparatus safety equipment
  • Fully compliant with OSHA workplace protection regulations
  • Tested and certified by independent safety testing authorities (including UL/CSA-related standards)

Maintenance

  • Chamber sliding door tracks and hinges feature self-lubricating, dust-resistant bushings requiring minimal maintenance.
  • Quarterly pressure decay check on the pneumatic interlock system ensures flawless valve cutoff performance.
  • OEM maintenance kits (including high-pressure O-rings, line filter screens, and specialized seal grease) ensure reliable gas-tight seals.

 

#Premium armored containment fill station providing world-class safety in high-pressure air cylinder operations.

#Integrates pneumatic interlocks, ergonomic tilt trays, customizable configurations (1 to 3 cylinder bays), and robust stainless-steel filling manifolds.

#NFPA 1901 compliant with a flawless safety record, making it the top choice for municipal fire departments and large-scale industrial safety bays.